This is a demo store. No orders will be fulfilled.

Details:
Description
Specification Model Cisco ASR 9912 Cisco ASR 9922
Categories Physical specifications
  • Height: 52.5 in. (1333.5 mm) (30 RU)
  • Width: 17.60 in. (447.04 mm)
  • Depth:
    • With door: 30.03 in. (762.76 mm)
    • Without doors: 29.25 in. (742.95 mm)
  • Weight:
    • 231.25 lb (105.11 kg) (3 PEMs and chassis)
    • 389.55 lb (177.07 kg) (3 PEMs, 2 Fan Trays, 2 RP2, and 5 Fabric Card 2)
  • Height: 77 in. (1955.4 mm) (44 RU)
  • Width: 17.60 in. (447.04 mm)
  • Depth:
    • With doors: 30.68 in. (779.27 mm)
    • Without doors: 30.19 in. (766.82 mm)
  • Weight:
    • 413 lb (187.73 kg) (4 PEM and chassis)
    • 639.5 lb (290.7 kg) (2 RP2, 7 Fabric Cards 2, 4 Fan Trays, and 4 PEMs)
Slot orientation Vertical Vertical
Cisco ASR 9000 Series RSP RSPs segregated into route processor and fabric cards RSPs segregated into route processor and fabric cards
Route processor Dual redundant route processors in 2 slots Dual redundant route processors in 2 slots
Fabric cards 6 + 1 redundant fabric cards 6 + 1 redundant fabric cards
Cisco ASR 9000 Series line cards 10 line-card slots 20 line-card slots
“Commons” components
  • 2 route processors
  • 7 fabric cards
  • 2 fan trays
  • 3 PEMs (either DC or AC)
  • 1 center fan filter, 2 side fan filters
  • 2 route processors
  • 7 fabric cards
  • 4 fan trays
  • 4 PEMs (either DC or AC)
  • 1 center fan filter, 2 side fan filters
Reliability and availability
  • Fabric redundancy
  • Fan redundancy
  • Feed redundancy
  • Power-supply redundancy
  • Route-processor redundancy
  • Software redundancy
  • Fabric redundancy
  • Fan redundancy
  • Feed redundancy
  • Power-supply redundancy
  • Route-processor redundancy
  • Software redundancy
Rack mounting
  • 19-in.
  • 21- and 23-in. adapters available
  • 19-in.
  • 21- and 23-in. adapters available
Cabinet mounting
  • Yes
  • Note: Doors not recommended in enclosed cabinets
  • Yes
  • Note: Doors not recommended in enclosed cabinets
Wall mounting No No
Airflow Front-to-back Front-to-back
Performance
  • Fabric
    • Seven switch fabric card slots:
    • Support for 6 + 1 redundancy
    • Operate in active/active nonblocking mode
    • Built-in service-intelligence and traffic-prioritization capability
  • Fabric
    • Seven switch fabric card slots:
    • Supports 6 + 1 redundancy
    • Operate in active/active nonblocking mode
    • Built-in service-intelligence and traffic-prioritization capability
Thermal
  • Two fan trays:
    • 12 high-efficiency fans per tray
    • Variable-speed fans for optimal thermal performance
    • No single point of failure
  • Four fan trays:
    • 12 high-efficiency fans per tray
    • Variable-speed fans for optimal thermal performance
    • No single point of failure
Power Modularity
  • Pay-as-you-grow power for future scalability, available in AC and DC
  • Multiple power module types:
    • 6 kW and 3 kW AC power modules
    • 4.4 kW and 2.1 kW DC power modules
  • Note: Mixing of AC and DC modules is not supported
  • Pay-as-you-grow power for future scalability, available in AC and DC
  • Multiple power module types:
    • 6 kW and 3 kW AC power modules
    • 4.4 kW and 2.1 kW DC power modules
  • Note: Mixing of AC and DC modules is not supported
Redundancy
  • AC: N+N redundancy
  • DC: N+1 redundancy
  • Power module redundancy
  • A/B Feed redundancy
  • PEM redundancy
  • AC: N+N redundancy
  • DC: N+1 redundancy
  • Power module redundancy
  • A/B Feed redundancy
  • PEM redundancy
Power zones
  • No power zone restrictions
  • Fully load-sharing power infrastructure
  • No power zone restrictions
  • Fully load-sharing power infrastructure
Power input
  • Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
  • Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
  • Worldwide ranging AC (200-240V; 50-60 Hz; 16A maximum)
  • Worldwide ranging DC (-40 to -72V; 50A nominal, 60A maximum)
Power module airflow Front-to-back Front-to-back
Environmental Specifications (All Entries Applicable to Cisco ASR 9912 and ASR 9922) Operating temperature (nominal) 41 to 104°F (5 to 40°C) 41 to 104°F (5 to 40°C)
Operating temperature (short-term) 23 to 131°F (-5 to 55°C) 23 to 131°F (-5 to 55°C)
Operating humidity (nominal) (relative humidity) 5 to 90% 5 to 90%
Storage temperature -40 to 158°F (-40 to 70°C) -40 to 158°F (-40 to 70°C)
Storage (relative humidity) 5 to 93% 5 to 93%
Operating altitude -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements) -60 to 4000m (up to 2000m conforms to IEC/EN/UL/CSA 60950 requirements)
Regulatory Compliance (All Entries Applicable to Cisco ASR 9912 and ASR 9922) Network Equipment Building Standards (NEBS)
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • SR-3580: NEBS Criteria Levels (Level 3)
  • GR-1089-CORE: NEBS EMC and Safety
  • GR-63-CORE: NEBS Physical Protection
  • VZ.TPR.9205: Verizon TEEER
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • SR-3580: NEBS Criteria Levels (Level 3)
  • GR-1089-CORE: NEBS EMC and Safety
  • GR-63-CORE: NEBS Physical Protection
  • VZ.TPR.9205: Verizon TEEER
ETSI standards
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • EN300 386: Telecommunications Network Equipment (EMC)
  • ETSI 300 019 Storage Class 1.1
  • ETSI 300 019 Transportation Class 2.3
  • ETSI 300 019 Stationary Use Class 3.1
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • EN300 386: Telecommunications Network Equipment (EMC)
  • ETSI 300 019 Storage Class 1.1
  • ETSI 300 019 Transportation Class 2.3
  • ETSI 300 019 Stationary Use Class 3.1
EMC standards emission
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • FCC Class 47CFR15 A
  • ICES 003 Class A
  • AS/NZS CISRP22 Class A
  • CISPR 22 (EN55022) Class A
  • VCCI Class A
  • BSMI Class A
  • IEC/EN 61000-3-12: Power Line Harmonics
  • IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
  • EN55022: Information Technology Equipment (Emissions)
  • EN 50121-4: Railway EMC
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • FCC Class 47CFR15 A
  • ICES 003 Class A
  • AS/NZS CISRP22 Class A
  • CISPR 22 (EN55022) Class A
  • VCCI Class A
  • BSMI Class A
  • IEC/EN 61000-3-12: Power Line Harmonics
  • IEC/EN 61000-3-11: Voltage Fluctuations and Flicker
  • EN55022: Information Technology Equipment (Emissions)
  • EN 50121-4: Railway EMC
EMC standards immunity
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
  • IEC/EN-61000-4-3: Radiated Immunity (10V/m)
  • IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
  • IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
  • IEC/EN-61000-4-5: Signal Surge Ports (1kV)
  • IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
  • IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
  • IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
  • IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • EN55024: Information Technology Equipment (Immunity)
  • EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EN 50121-4: Railway EMC
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
  • IEC/EN-61000-4-3: Radiated Immunity (10V/m)
  • IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
  • IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
  • IEC/EN-61000-4-5: Signal Surge Ports (1kV)
  • IEC/EN-61000-4-5: Surge DC Port (1kV CM, 1kV DM)
  • IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
  • IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
  • IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • EN55024: Information Technology Equipment (Immunity)
  • EN50082-1/EN-61000-6-1: Generic Immunity Standard
  • EN 50121-4: Railway EMC
Safety
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • UL/CSA/IEC/EN 60950-1
  • IEC/EN 60825 Laser Safety
  • ACA TS001
  • AS/NZS 60950
  • FDA Code of Federal Regulations Laser Safety
  • Cisco ASR 9912 and ASR 9922 Routers are designed to meet:
  • UL/CSA/IEC/EN 60950-1
  • IEC/EN 60825 Laser Safety
  • ACA TS001
  • AS/NZS 60950
  • FDA Code of Federal Regulations Laser Safety

CONTACT US TO LEARN MORE

ABOUT Cisco ASR 9912

Fill out the form and our team will get back to you.

What are you looking for?