This is a demo store. No orders will be fulfilled.

Details:
Description
Description Specification
Physical dimensions (includes ejector bracket/lever); (H x W x D); weight
  • ASR 9902 chassis (including 2 RPs, 2 PSUs, 3 FANs): H x W x D: 3.45 x 17.3 x 19 in.; 46.39 lb (87.63 x 439.74 x 482.60 mm; 21.04 kg)
  • Note: Excluding ejector, the depth is 19 in./482.6 mm
Redundancy
  • Route processor redundancy
  • Power supply redundancy
  • Fan redundancy
  • Software redundancy
Port density
  • ASR 9902 chassis with integrated ports:
  • 2 QSFP-DD ports capable of 10Gb, 40Gb, and 100Gb Ethernet
  • 6 QSFP28 ports capable of 10Gb, 40Gb, and 100Gb Ethernet
  • 16 SFP28 dual-rate ports capable of 25Gb and 10Gb Ethernet
  • 24 SFP+ ports capable of 10Gb Ethernet (LAN) and WAN (OTN)
RP CPU memory SDRAM DDR4 – 32GB
Rack mounting 2-post and 4-post 19-in. and 23-in.
Airflow Front to back
Power
  • 1.6 kW DC power module (up to 2 modules), redundancy: 1+1
  • 1.6 kW AC power module (up to 2 modules), redundancy: 1+1
  • Note: Mixing of AC and DC modules is not supported.
Ethernet
  • 10-Gbps IEEE 802.3ae compliant
  • 25-Gbps IEEE 802.3by and IEEE 802.3cc compliant
  • 40/100-Gbps IEEE 802.3ba compliant
  • 100 Gigabit Ethernet PHY monitoring
  • IEEE 802.x flow control
  • Full-duplex operation
  • Per-port byte and packet counters for policy drops; oversubscription drops; Cyclic Redundancy Check (CRC) error drops; packet sizes; and unicast, multicast, and broadcast packets
Performance
  • 10-Gbps line-rate throughput per SFP+ port
  • 25-Gbps line-rate throughput per SFP28 port
  • 100-Gbps line-rate throughput per QSFP28 or QSFP-DD port
Operating temperature 41 to 104°F (5 to 40°C)
Note: Limitations may apply when using high-power optics
Operating humidity (nominal) (relative humidity) 10 to 85%
Storage temperature –40 to 158°F (–40 to 70°C)
Storage (relative humidity) 5 to 95%
Note: Not to exceed 0.024 kg of water per kg of dry air
Operating altitude 0 to 4000 m
Note: Limitations may apply when using high-power optics
ETSI/EN standards
  • The Cisco ASR 9902 Router is designed to meet:
  • EN300 386: Telecommunications Network Equipment (EMC)
  • ETSI 300 019 Storage Class 1.1
  • ETSI 300 019 Transportation Class 2.3
  • ETSI 300 019 Stationary Use Class 3.1
  • EN55022: Information Technology Equipment (Emissions)
  • EN55024: Information Technology Equipment (Immunity)
  • EN50082-1/EN-61000-6-1: Generic Immunity Standard
EMC standards
  • The Cisco ASR 9902 Router is designed to meet:
  • FCC Class A
  • ICES 003 Class A
  • AS/NZS 3548 Class A
  • CISPR 22 (EN55022) Class A
  • VCCI Class A
  • BSMI Class A
  • IEC/EN 61000-3-2: Power Line Harmonics
  • IEC/EN 61000-3-3: Voltage Fluctuations and Flicker
  • EN50121-4 Railway Applications Part 4: Emission and immunity of the signaling and telecommunications apparatus
Immunity
  • The Cisco ASR 9902 Router is designed to meet:
  • IEC/EN-61000-4-2: Electrostatic Discharge Immunity (8kV Contact, 15kV Air)
  • IEC/EN-61000-4-3: Radiated Immunity (10V/m)
  • IEC/EN-61000-4-4: Electrical Fast Transient Immunity (2kV Power, 1kV Signal)
  • IEC/EN-61000-4-5: Surge AC Port (4kV CM, 2kV DM)
  • IEC/EN-61000-4-5: Signal Ports (1kV)
  • IEC/EN-61000-4-5: Surge DC Port (1kV)
  • IEC/EN-61000-4-6: Immunity to Conducted Disturbances (10Vrms)
  • IEC/EN-61000-4-8: Power Frequency Magnetic Field Immunity (30A/m)
  • IEC/EN-61000-4-11: Voltage DIPS, Short Interruptions, and Voltage Variations
  • EN 50121-4: Railway EMC
Safety
  • The Cisco ASR 9902 Router is designed to meet:
  • UL/CSA/IEC/EN 60950-1
  • IEC/EN 60825 Laser Safety
  • ACA TS001
  • AS/NZS 60950
  • FDA: Code of Federal Regulations Laser Safety
Network Equipment Building Systems (NEBS)
  • The Cisco ASR 9902 Router is designed to meet:
  • SR-3580: NEBS Criteria Levels (Level 3)
  • GR-1089-CORE: NEBS EMC and Safety
  • GR-63-CORE: NEBS Physical Protection

CONTACT US TO LEARN MORE